With an excellent signal to noise ratio and a variety of echo extraction algorithms available, Reflex's proven software is capable of tracking the right echo in the most difficult of environments.
Five relays, isolated analogue output, dual serial ports, integral keypad and multiline display provide a complete standalone instrument capable of taking control of any application.
MULTIPLE POWER SUPPLIES Reflex accepts power supplies of 110 or 230 volt AC and will automatically detect which one is being used. A separate 24 volt DC input is provided on every unit for those who want to operate on a safe DC voltage or provide backup in case of power failure.
MULTI-FUNCTIONAL 5 programmable relays allow alarms and controls to be set with variable hysteresis anywhere throughout the instrument's span and the analogue output can be configured to go full scale, anywhere within the overall range of the Reflex. |