A display
of the operating parameters is also available at the touch of a
button for the milliamp output, distance, level, echo confidence
and temperature of the transducer.
| PERFORMANCE
SPECIFICATION |
|
| Measuring
principle |
Non-contact
Ultrasonic |
| Measuring
range |
6
Metres maximum on liquids |
| Measuring
modes |
Level
or distance |
| Accuracy
of change in level |
-/+
0.25% of measured distance |
| Resolution |
2mm
or 0.1% of empty distance |
|
(whichever
is greater) |
| Damping |
Adjustable |
| Blanking |
Adjustable |
| |
|
| HARDWARE
SPECIFICATION |
|
| Power
supply |
20-30
VDC |
| Analogue
output |
4-20
mA \ 12 bit \Loop Powered |
| Ambient
Temperature |
-40
to + 70Deg C |
| Display |
4
digit 12mm LCD |
| Interface |
5
Push buttons |
| Temperature
compensation |
Integral
in RZT Transducer / IP68 |
| Enclosure |
IP65
Polycarbonate 170x120x55mm |
| Approvals |
Certified
EExm ll T6 Transducer (Zones 1 and 2) |
|