| HYCONTROL
CAPACITIVE LEVEL SWITCH RANGE |
 |
Hycontrol
ME capacitive level switches provide simple, accurate
and reliable level control for a wide range of applications.
They are suitable for use on liquids, solids, slurries,
pastes, granules, powders and pellets in high temperature,
high pressure and corrosive environments.
Unlike some other capacitive switches, this unit works
independently of the tank walls using an integral grounding
sleeve without the need for a reference probe, which enables
it to be used in concrete, plastic or other non metalic
tanks.
This technology also provides an ideal solution for interface
detection applications such as oil on water and liquid
detection underneath a layer of foam. |
| |
| CAPACITIVE
SWITCH FEATURES |
| •
Easy installation through a 1” BSP process fitting
• High corrosion and chemical resistance as standard
options
• Universal design can be used for high or low
level detection
• Multiple versions with rod and cable to simplify
mounting options
• High temperature versions up to 800 °C
• Low maintenance technology with no moving parts
• Hazardous area certified versions ATEX approved
• Adjustable sensitivity for a wide range of products
• Adjustable time delay to stop spurious signals
from surface ripple
• Anti-static probes for plastic pellet applications
with high static probability
• Remote electronics option for high vibration
applications
• Interface level detection for difficult applications
|
| |
| CONSTRUCTION |
|
1.
Probe : 304SS or 316SS
2. Insulation : UPE or PTFE
3. Grounding Sleeve : 304SS or
316SS
4. Connection : 1" BSP standard
5. Housing : Aluminum IP65 epoxy
coated |
6.
Conduit entry : ½" BSP
7. Housing O-Ring : NBR
8. PC board : A, B, C, D Type
9. Sensitivity adjustment : 10pF,
20pF, 40pF
10. Cover : Aluminum epoxy coated |
|
| |
| STANDARD
GENERAL PURPOSE VERSIONS |
 |
Dimension |
|
|
|
| Model |
ME10
A/B/C |
[STANDARD
TYPE] |
|
ME11
A/B/C |
| [
STANDARD TYPE] |
|
| ME20
A/B/C |
| [
HI-TEMP. TYPE ] |
|
Operating
Temp. |
-20°C~80°C
|
-20°C~80°C |
-20°C~200°C |
Probe
Material |
304SS
|
304SS
|
304SS |
Insulation
Material |
UPE |
UPE |
PTFE |
Connection |
1"BSP
|
1"BSP
|
1"BSP
|
Sensitivity
Range |
10pF,
20pF, 40pF |
10pF,
20pF, 40pF |
10pF,
20pF, 40pF |
Weight |
Approx.
1.9kg |
Approx.
1.9kg |
Approx.
2.4kg |
Enclosure
Details |
Aluminum
IP65 |
Supply
Voltage |
110/220VAC
±10% or 24VDC |
Delay
Time |
0~6
seconds |
Power
Consumption |
2W |
Contact
Rating |
5A/240VAC
or 5A/30VDC, SPDT or NPN 100mA |
|
| |
| HIGH
TEMPERATURE AND CORROSION RESISTANT VERSIONS |
 |
Dimension |
|
|
|
| Model |
|
ME30
A/B/C |
| [CORROSION-PROOF] |
|
| ME32
A/B/C |
| [
CORROSION-PROOF ] |
|
Operating
Temp. |
-20°C~800°C
|
-20°C~80°C |
-20°C~200°C |
Probe
Material |
304SS
|
304SS
|
Wetted
part: PVDF coating |
Insulation
Material |
CERAMIC |
Wetted
part: PVDF coating |
UPE |
Connection |
2"x5kg/cm2 JIS Flange |
1-1/2"x10kg/cm2 JIS Flange (UPE) |
1-1/2"x10kg/cm2 JIS Flange (SS) with PVDF
Washer (5mm) |
Sensitivity
Range |
10pF,
20pF |
10pF |
10pF,
20pF |
Weight |
Approx.
6.5kg |
Approx.
2kg |
Depends
on the length |
Enclosure
Details |
Aluminum
IP65 |
Supply
Voltage |
110/220VAC
±10% or 24VDC |
Delay
Time |
0~6
seconds |
Power
Consumption |
2W |
Contact
Rating |
5A/240VAC
or 5A/30VDC, SPDT or NPN 100mA |
|
| |
| REMOTE
AND CABLE VERSIONS |
 |
Dimension |
|
|
|
| Model |
ME40
A/B/C |
[REMOTE
PROBE TYPE] |
|
ME50
A/B/C |
| [
WIRE-PROBE TYPE] |
|
| ME60
A/B/C |
| [
PLATE TYPE ] |
|
Operating
Temp. |
-20°C~100°C
|
-20°C~80°C |
-20°C~80°C |
Probe
Material |
304SS
|
304SS
cable |
304SS |
Insulation
Material |
UPE |
UPE |
UPE |
Connection |
1"BSP
(SS) |
1"BSP (SS) |
2-1/2"x5kg/cm2 JIS Flange (SS) |
Sensitivity
Range |
10pF |
10pF,
20pF, 40pF |
10pF,
20pF, 40pF |
Weight |
Approx.
3kg |
Approx.
4.1kg |
Approx.
3.2kg |
Enclosure
Details |
Aluminum
IP65 |
Supply
Voltage |
110/220VAC
±10% or 24VDC |
Delay
Time |
0~6
seconds |
Power
Consumption |
2W |
Contact
Rating |
5A/240VAC
or 5A/30VDC, SPDT or NPN 100mA |
|
| |
| INTRINSICALLY
SAFE VERSIONS FOR HAZARDOUS AREAS |
 |
Dimension |
|
|
|
| Model |
ME70D
(with EX-75) |
| [STANDARD
TYPE] |
|
ME72D
(with EX-75U) |
| [
HI-TEMP. TYPE] |
|
| ME75D
(withEX-75U) |
| [
WIRE PROBE TYPE ] |
|
Operating
Temp. |
-20°C~80°C
|
-20°C~200°C |
-20°C~80°C |
Probe
Material |
304SS
/ 316 SS |
304SS
/ 316 SS |
304SS
/ 316 SS
cable |
Insulation
Material |
PTFE
or UPE |
PTFE
or UPE |
PTFE
or UPE |
Connection |
1"BSP
(SS) |
1"BSP (SS) |
1"BSP
(SS) |
Sensitivity
Range |
10pF,
20pF, 40pF |
10pF,
20pF, 40pF |
10pF,
20pF, 40pF |
Weight |
Approx.
1.9kg |
Approx.
2.4kg |
Approx.
4.1kg |
Enclosure
Details |
Aluminum
IP65 |
Supply
Voltage |
16~24VDC |
Enclosure
Protection |
ATEX
EEx ia iiC (*) |
Power
Consumption |
2W |
Contact
Rating |
NPN 100mA |
|
| |
| INTRINSICALLY
SAFE VERSIONS FOR HAZARDOUS AREAS |
 |
Dimension |
|
|
|
| Model |
ME76D
(with EX-75) |
| [PLATE
TYPE] |
|
ME77D
(with EX-75U) |
| [
ANTI-STATIC TYPE] HI-TEMP. |
|
| ME78D
(withEX-75U) |
| [
ANTI-STATIC TYPE ] |
|
Operating
Temp. |
-20°C~80°C
|
-20°C~200°C |
-20°C~80°C |
Probe
Material |
304SS
/ 316 SS |
PTFE
or UPE coating |
PTFE
or UPE coating |
Insulation
Material |
PTFE
or UPE |
PTFE
or UPE |
PTFE
or UPE |
Connection |
2-1/2"x5kg/cm2
JIS Flange (SS) |
1"BSP (SS) |
1"BSP
(SS) |
Sensitivity
Range |
10pF,
20pF, 40pF |
10pF,
20pF |
10pF,
20pF |
Weight |
Approx.
3.2kg |
Approx.
3.1kg |
Approx.
2kg |
Enclosure
Details |
Aluminum
IP65 |
Supply
Voltage |
16~24VDC |
Enclosure
Protection |
ATEX
EEx ia iiC (*) |
Power
Consumption |
2W |
Contact
Rating |
NPN 100mA |
|
| |
| ANTI-STATIC
AND TEFLON PROBE VERSIONS |
 |
Dimension |
|
|
| Model |
ME80
A/B/C |
| [ANTI-STATIC
TYPE] |
|
ME81
A/B/C |
| [
ANTI-STATIC TYPE] HI-TEMP. |
|
Operating
Temp. |
-20°C~80°C
|
-20°C~200°C |
Probe
Material |
UPE
coating |
PTFE
coating |
Insulation
Material |
UPE |
PTFE |
Connection |
1"BSP
(SS) |
1"BSP (SS) |
Sensitivity
Range |
10pF,
20pF |
10pF,
20pF |
Weight |
Approx.
2kg |
Approx.
2.5kg |
Enclosure
Details |
Aluminum
IP65 |
Supply
Voltage |
110/220VAC
±10% or 24VDC |
Delay
Time |
0-6
seconds |
Power
Consumption |
2W |
Contact
Rating |
5A/240VAC or 5A/30VDC, SPDT or NPN 100mA |
|
| |
| HAZARDOUS
AREA INTRINSICALLY SAFE VERSION |
 |
| EX-75U
Zener barrier provides intrinsic safety to the ME7D
type level switch by limiting the current from the
control module in the safe area to the level switch
in the hazardous zoned area.Please contact the office
for a copy of the certificates and more information
if required. |
 |
| 1.
Supply voltage : |
110
/ 220VAC |
| 2.
Power consumption : |
2W |
| 3.
Input signal : |
NPN
transistor |
| |
resistance Ri= 500W |
| 4.
Output voltage : |
16~24
VDC |
| 5.
Short circuit current : |
25mA
max. |
| 6.
Relay output : |
SPDT
|
| |
10A
/30VDC |
| |
10A
/220VAC |
| 7.
Operating temp. : |
-20°C
~ 60°C |
| 8.
Weight : |
0.3
kg |
| 9.
Enclosure mounting : |
DIN
Rail |
|
 |
|
|
| |
| ADJUSTMENT |
 |
| COARSE
CALIBRATION
With
the probe in contact with the material being detected,
set the SENSITIVITY ADJ pointer to position H
and then using a blade screwdriver set the COARSE
adjustment until the INDICATOR lamp is on. Rotating
the COARSE adjustment clockwise and counter-clockwise
will turn the INDICATOR lamp on and off. Ensure
the lamp is on before moving on to adjusting the
sensitivity. |
000 |
DELAY
FUNCTION SETTING
This
feature is used to stop any spurious signals to
the switch from surface ripple or agitation of
the product. It also protects the relay from premature
wear by eliminating contact chatter by adding
a small time delay from when product contacts
the probe .
The
factory setting is zero seconds with the DELAY
screw fully counter clockwise.
Turning the screw in a clockwise direction introduces
a delay between the INDICATOR lamp coming on and
the relay changing its state. |
|
|
| SENSITIVITY
ADJUSTMENT
After
setting the COARSE calibration the INDICATOR lamp
will switch on when probe is touching the material
and off when in free air.
Make sure the probe is in contact with the material
and then turn the SENSITIVITY ADJ knob clockwise
until the INDICATOR lamp turns off. Set the SENSITIVITY
ADJ pointer half way between H and the point that
the INDICATOR lamp switches off.
|
|
|
|
|
|
| |
| INSTALLATION
GUIDE |
 |
| |
|
|
| The
grounding sleeve must be mounted to protrude at
least 30mm from the vessel wall. |
For
the ME60 type to be mounted properly the vessel
walls should not exceed 25mm thickness. |
To
prevent false readings on solids applications it
is best to make sure the material flows symmetrically.
If the inlet is not located in the centre portion
of the tank roof, check the flow pattern (a angle)
of your material and place the probe in the
Appropriate location. |
|
|
|
If
the probe is mounted on the top, make sure the length
of probe is enough to touch the highest level of
raw material.
The ME50 type must have at least 300mm from the
silo wall.
The ME60 type is usually
Located at the lower position. |
For
Non-Stationary or material that will be vibrated
a separate control unit such as the ME40 type is
recommended. |
Where
possible install the probe away from the inlet to
reduce the risk of inflowing material damaging the
probe. If the probe is near an inlet, we recommend
placing a protective cover 200mm above the probe.
The cover should be parallel to the probe and the
same length . |
|
|
|
| |
|
|
|
|
|
If
multiple probes are mounted
In the same vessel they must be separated by at
least 300 mm to reduce probe to probe interference
. |
The
probe should not be mounted underneath a liquid
inlet otherwise it will switch on erroneously. |
If
the tank is equipped with an agitator, please use
the time-delay function to stop spurious signals |
|
|
|
| The
cable inlet should face downward to avoid rainwater
ingress. |
Mounting
the probe at a 20° incline optimizes the results
and increases the switch sensitivity. |
Mounting
the probe at top of tank will help avoid material
bridges from forming and reduce false alarms. |
|
| |
| ORDER
INFORMATION |
 |
| |
 |
•Tolerance
of the total product length is ±5mm.
•Characteristics, specifications and dimensions
are subject to change without notice.
•Please contact Hycontrol if you have a special
request not mentioned in the above
|
 |
Hycontrol
Level switches with this option have an additional
pair of terminals provided in the switch head that
simply require a push button switch to connect these
two terminals together and this is usually mounted
at ground level local to the silo fill point.
After
pushing this button the circuit is then loaded
as if a product has touched the active part of
the probe and the electronics (if working correctly)
will detect this change in capacitance and activate
the relay to change its state. Any audio or visual
alarms wired to this relay will then be activated
and will continue until the ground level test
button is released. If the test is successful
then the operator can then proceed to fill the
silo, confident that the high alarm will operate
if required to do so.
Hycontrol
provide a complete alarm and test panel solution
for single or multipoint applications however
a simple push button can easily be retrofitted
to existing panel installations with little or
no disruption to the plant operations providing
the alarms and sirens already exist!
This
ground level test facility is offered as an option
on Hycontrol’s range of capacitive, admittance